Covid-19 Products
Covid-19 Test
- Screening and Confirmation
Covid-19 Sample / Specimen Collection
Body Temperature Measurement
Disinfection & Contamination Control
Vaccine Storage & Transport
PPE Personal Protection Equipment
Covid-19 Related Laboratory Supplies
Item
Specifications
Accuracy
Sensitivity: 100%; Specificity: 100%
Capacity
96 results within 2 hours
Kit Composition
qRT-PCR reaction mix, qRT-PCR enzyme mix, negative, positive and internal control
Item
Specifications
32 Tests Kit
Applicable for automatic ectraction process using ALLSHENG Auto-Pure 32A System (closed system)
48 Tests Kit
Applicable for manual extraction process
Item
Specifications
Stability
12 months from date of purchase when stored properly
Capacity
96 tests | can be customized
Kit Composition
Proteinase K Buffer, SuperMAG Beads, Carrier RNA and Buffers - VAL, RW1, RW2 and AVE
Item
Specifications
Accuracy
Stable for 12 months when stored properly (15-25°C)
Capacity
96 tests in less than 1 hour
Kit Composition
Plate 1 (buffer MVN), Plate 2 (buffer DW1P), Plate 3 (buffer MWP, FineMag Particles G), Plate 4 (RNase-Free ddH2O) and 96 tip comb
Item
Specifications
Throughput
1~96 per batch
Total Volume
Less than 1000μl
Particle Efficiency
Size & Weight
685 x 600 x 390 mm; 40 kg
Item
Specifications
Stability
Stable for 12 months when stored properly (15-25°C)
Capacity
32 results in less than 1 hour
Kit Composition
Prefilled 96 well plates (buffer (MVN, DW1P, MWP), FineMag Particles G and RNase-Free ddH2O) and 8-rod covers
Item
Specifications
Throughput
1~32 per batch, 2 plates
Total Volume
20~1000μl
Particle Efficiency
>95%
Size & Weight
320 x 350 x 300 mm; 15 kg
Item
Specifications
Throughput
1~32 per batch
Total Volume
50~1000μl
Magnetic Beads
Recycling Rate
>95%
Size & Weight
40 x 47 x 45 cm; 28 kg
Item
Specifications
Throughput
1~96 per batch
Total Volume
50~1000μl
Magnetic Beads
Recycling Rate
>95%
Size & Weight
56 x 62 x 50 cm; 54 kg
Item
Specifications
Throughput
1~48 per batch
Reaction Volume
5~100μl
Detection Time
2 seconds for 48 wells for all channels
Size & Weight
260 x 400 x 260 mm; 11 kg
Item
Specifications
Throughput
1~96 per batch
Total Volume
50~1000μl
Detection Time
7 seconds for 96 wells for all channels
Size & Weight
355(W) x 475(L) x 484(H) mm; 30 kg
Item
Specifications
Sample Capacity
0.1ml PCR tubes x96, 8x 12 PCR plate or 96 well plate x1
Reaction Volume
10~50μl
Fluorescent Channels
4 / 6 channels
Sensitivity
Single copy gene
Item
Specifications
Sample Capacity
2 channels. 2 samples simultaneously or separately.
Sample Volume
500μl
Target Gene
RdRp & E or RdRp & N
55 minutes
Detection Time
Item
Specifications
Accuracy
Sensitivity: (IgM) 93.7%; (IgG) 98.8%
Specificity: (IgM) 99.1%; (IgG) 98.7%
Packing Size
25 tests/pack. Each pack contains 25 IgG/IgM test cassettes*, 5μL disposable pipettes, 3mL buffer
*contains preservative sodium azide: <0.02% (7.5ng/test)
Item
Specifications
Accuracy
Specificity of >99.9 %; Sensitivity of 97.56% with high viral loads (Ct range 20-30)
Packing Size
20 tests/pack. (test cassettes, nasopha-ryngeal swabs, extraction tubes (dropper caps, reagent holder, buffer bottle), IFU)
Item
Specifications
Accuracy
Specificity of 100%; Sensitivity of 100%
Packing Size
1 test/pack. 5 test/pack. 25 tests/pack. (Test cassette(s), extraction buffer tube(s) with dropper cap(s), nasal swab(s), biohazard disposable bag, IFU)
Item
Specifications
Accuracy
Nasal: Specificity 100%; Sensitivity 93.3%
Saliva: Specificity 100%; Sensitivity 90%
Packing Size
1 test/pack. 5 test/pack. 25 tests/pack. (Test cassette(s), extraction buffer tube(s) with dropper cap(s), nasal swab(s), biohazard disposable bag, IFU)
Item
Specifications
Accuracy
Specificity of 100%; Sensitivity of 100%
Packing Size
1 test/pack. 5 test/pack. 25 tests/pack. (Test cassette(s), extraction buffer tube(s) with dropper cap(s), nasal swab(s), biohazard disposable bag, IFU)